Static Data Dependencies

Dependencies - Static Data

  • From Well Parameter (Planning) or Interventions (Real-time):

    • Trajectory

      • Measured Depth

      • Inclination

      • Azimuth

  • From Interventions -> Sections -> Run:

    • Fluids

      • Density

      • Rheological model

    • Wellbore

      • Inner Diameter

      • Start Depth

      • End Depth

    • Drill String

      • Outer Diameter

      • Inner Diameter

      • Length

      • linear weight

    • BHA

      • Outer Diameter

      • Inner Diameter

      • Length

      • Linear weight

      • TFA (Drill bit and Underreamers)

Return to Sea Bed

When on a wellbore the first component (last Casing or open hole) starts at a depth greater than zero of the algorithm, as in the below example, the water depth is 500 m. It works for hydraulics, torque and drag, and general equations.

Last updated