Live Drilling
  • Introduction
  • FAQ
  • what's new
    • Latest releases
      • Wells 5
      • LiveRig 5
      • LiveRig 4
      • WITSML Store
    • Operations in Time by Depth Chart
    • Unit Sets
      • Per-Asset Units
      • Unit Conversion
      • Dashboard Configuration
      • Force Follow Asset Units
    • Well casing shoe schematic
    • Wells correlation
    • FFT spectrum
    • Pressure Tests
      • Configuration
      • Automated Standard Pressure Tests
      • Manual Pressure Test
      • LOT/FIT
    • Rig State detection
    • BOP Schematic
      • BOP status register
    • Signal Processing
      • Moving Average
  • Data Flow
    • Introduction
    • Data Ingestion
    • Data Normalization
      • Clock Synchronization
      • Normalized events schema
      • Data indexes and enrichment
      • Unit conversion
      • Auto-Switch
  • Physical Models
    • Introduction
      • Structure of the functions
      • Validation
    • General Equations
      • Static Data Dependencies
      • Pipes Functions
    • Trajectory
      • Introduction
      • Static Data Dependencies
      • Pipes Functions
    • Hydraulic
      • Introduction
      • Static Data Dependencies
      • Pipes Functions
    • Torque and Drag
      • Introduction
      • Static Data Dependencies
      • Pipes Functions
    • Hole Cleaning
      • Introduction
      • Static Data Dependencies
      • Pipes Functions
    • Surge and Swab
      • Introduction
      • Static Data Dependencies
      • Pipes Functions
    • Thermal
      • Introduction
    • Volume Tracker
      • Introduction
      • Pipes Functions
  • Basic Features
    • Charts
      • Channels Charts
        • Temporal Channels Chart
        • Channel Value Chart
        • Depth Channels Chart
        • Data navigation
          • Span Control
      • Rig Allocation Gantt Chart
    • Unit sets
      • Configuration changes on unit sets
      • Depth unit changes
      • Personal units sets
    • Permission schema
    • Import/Export Well
    • Add-ons
  • Static Data
    • Assets
      • Assets Structure
    • Well
      • Introduction
      • Well Schema
      • Well Units
      • Regions, fields and countries
      • Well Design Overview
      • Objectives
    • Intervention
      • Introduction
      • Intervention Schema
      • Intervention Types
      • Scenarios
      • Runs
      • Completion and Abandonment
      • Drilling Section Schema
    • Rig
      • Introduction
      • Rig Schema
      • Physical models configuration
    • Pipes functions
    • REST API Examples
  • Administration
    • High Frequency Data
      • WITSML Null Values
      • Unit Management Tools
      • WITS Custom Mapping
    • Data Normalization
      • Data Management
        • Event Settings
        • Channels Management
      • Data normalization templates
      • Data normalization templates prioritization
      • Auto-Switch
    • Standard Identifiers
    • Static Data
      • Regions, fields and countries
      • Intervention Types
  • LiveRig Collector
    • Introduction
    • Getting Started
    • Connecting to Intelie Live
    • Security
    • Local data storage
    • Data transmission and recovery
    • Monitoring
    • Remote Control
      • APIs
        • /testSourceEndpoint
        • /storeConfiguration
        • /getFromStore
        • /backlog-sync
      • Sources
        • MQTT Topics
        • OPC Requests
        • WITSML Backlog Sync
        • WITSML Object Explorer
        • WITSML Requests
      • Properties
    • HA Deployment
    • Protocols
      • WITSML
      • WITS
      • OPC-DA
      • OPC-UA
      • MODBUS
      • MQTT
      • CSV
      • RAW
    • Protocol conversion
    • Configuration
      • liverig.properties
      • sources.xml
      • store.json
      • modbus.json
      • mqtt.json
      • Configuring an OPC-UA source
      • Multiple event types for WITSML sources
      • Certificate-based authentication for WITSML HTTPS sources
    • LiveRig Collector Appliance
    • Command line Interface (CLI)
  • LIVE EDGE
    • Collector Reader
  • Integrations
    • Introduction
    • WITSML Store
    • REST Output
    • REST Input
    • WellView
    • OpenWells
    • Python
  • DEVELOPER
    • Identified Curves
    • Hidden Units
  • DEPRECATED
    • WITSML Output
    • LiveRig 3.x / 2.x
      • 3.5.0
      • 3.4.0
      • 3.3.0
      • 3.2.0
      • 3.1.0
      • 3.0.0
      • 2.29.0
Powered by GitBook
On this page
  • Auto-Switch indicator
  • Buttons
  • Create Template
  • Import Template
  • Not Configured Channels
  • Expand
  • Edit
  • Target Channel
  • Data Quality
  • Target Channel
  • Current Value
  • Priority
  • Source
  • Input Channel
  • Filter (pipes)
  • Input Channel
  • Status
  • Priority
  • Source
  • Input Channel
  • Current Value
  • Override Input Unit
  • Filter (pipes)
  • Depth Channel

Was this helpful?

  1. Administration
  2. Data Normalization
  3. Data Management

Channels Management

Channels Management can be accessed from the data management tab (which is located at Asset Pages)

PreviousEvent SettingsNextData normalization templates

Last updated 2 years ago

Was this helpful?

Auto-Switch indicator

If you don't know what is the Auto-Switch feature, consider these readings: - -

Indicates if the Auto-Switch feature is enabled, considering if this feature is on and enabled for the current Asset.

If the Auto-switch is ON, but the normalization is OFF to the Asset, a warning will be displayed:\

Buttons

Create Template

Intelie Live supports data normalization templates to speed up the configuration of the normalization. If assets have part of their sources configuration in common, e.g. the same service company, then a template can be used to define that configuration.

Create template option will create a template with all channels configured in this asset. That is useful to save the same configuration and apply it for other assets.

Import Template

Import template option allows the selection of an already saved template to import to this asset. Imported channels will be merged to already configured ones.

By selecting “Prioritize the channels selected on this template for the selected assets”, the template channels will be imported and selected. If this option is off, the selected channels will be the ones that already exist.

The templates can be managed on the system configuration.

Be aware that the only fields saved are:

  • Target channel

  • Input channel

  • Priority

  • Filter pipes

  • Depth channel (if applicable )

Not Configured Channels

Clicking at the "Not Configured Channels" button the user can visualize a list of channels that were not yet used as input channels.

Expand

Shows the "Data Management" card in full-screen mode.\

Edit

Toggles the Channels Management edit mode. During the edit mode, input and target channels status and value are not updated.

Target Channel

Data Quality

Target Channel

A standard Channel

Current Value

The current value of the normalized channel. This is the input channel value converted to the target channel's unit.

Priority

Selected input channel priority

Source

Selected input channel source

Input Channel

Selected input channel. If the Auto-Switch is OFF, the selected channel is was defined manually by the user.

Filter (pipes)

Selected input channel filter

Input Channel

Status

Priority

Source

Optional field used for notes. An asset that uses the Channels Management can choose between displaying this field to the user or not.

Input Channel

Current Value

Input Channel's current value together with its unit.

Override Input Unit

This functionality allows the user to overwrite the unit received in the input channel. It can be really useful when the input channel is misconfigured, or when the unit is represented differently from what is defined in Live.

Take as an example an input channel that receives value in meters:

As Live does not understand meters , only m, there will be a unit conversion error in normalization. To solve that, the user can define the Override Input Unit as m. This way, Live will treat the received data as m, and not meters. Please note that the override input unit does not perform any conversion. As the name suggests, it only overrides the unit. It's also important to mention that the Override Input Unit field is compatible (i.e. can be converted to) with the Target Channels' unit.

Filter (pipes)

under construction

Depth Channel

under construction

If the Auto-Switch is disabled for the Asset (in the card) or if it's disabled for the entire Live (via the menu Configurations > Additional Features > Auto-Switch), the indicator will be OFF:\

This list represents the raw events filtered by the Event Settings > Pipes filter (see ).

A numeric field that is used to define the priority of the curve. It's not possible to define duplicated priorities or negative numbers. It's used by the Auto-switch (see , and )

The channel to be normalized. This field has an autocomplete feature, that shows the possible input channels (the same ones displayed at "").

If you want the meters unit (or any other) to be recognized by the hole Live, consider creating an alias or a unit extension in the .

Event Settings
Data Filtering
Data flow > Auto-Switch
Administration > Auto-Switch
Unit Management Tools screen
not configured channels
Data flow > Auto-Switch
Administration > Auto-Switch
Auto-switch OFF
Auto-switch is ON, but not working since there normalization is OFF
Buttons to create a template from an asset and import a template into an asset.
Create template by asset example (checked rows will be included on saved template)
Example of templates configuration
Not normalizing, not configured or unknown data quality
Invalid generated event type
OK
No data received in time window. The time window can be configured at Configurations > Additional Features > Auto-Switch > Substitute channels that have not transmitted for more than.
Override Input Unit error
No data received in time window. The time window can be configured at Configurations > Additional Features > Auto-Switch > Substitute channels that have not transmitted for more than.
OK
"Override Input Unit" conversion error
Conversion error